The closed cell construction has many great features such as soft resistance refractive index, cold resistance, fire-retardant, waterproof, low thermal conductivity, shock and sound absorption and so on. It can be widely used in large-scale central and home air conditioning, construction, chemicals, textile and electrical industries.
| Technical Data | |||
|---|---|---|---|
| Property | Unit | Value | Test Method |
| Temperature range | °C | (-50 - 110) | GB/T 17794-1999 |
| Density range | Kg/m³ | 45-65Kg/m³ | ASTM D1667 |
| Water vapor permeability | Kg/(m.s.pa) | ≤0.91×10⁻¹³ | DIN 52 615 / BS 4370 Part 2 1973 |
| μ | - | ≥10000 | - |
| Thermal Conductivity | W/(m.k) | ≤0.030 (-20°C) | ASTM C 518 |
| ≤0.032 (0°C) | |||
| ≤0.036 (40°C) | |||
| Fire Rating | - | Class 0 & Class 1 | BS 476 Part 6 part 7 |
| Flame Spread and Smoke Developed Index | - | 25/50 | ASTM E 84 |
| Oxygen Index | - | ≥36 | GB/T 2406, ISO4589 |
| Water Absorption, %by Volume | % | 20% | ASTM C 209 |
| Dimension Stability | - | ≤5 | ASTM C534 |
| Fungi resistance | - | Good | ASTM 21 |
| Ozone resistance | Good | GB/T 7762-1987 | |
| Resistance to U.V. and weather | Good | ASTM G23 | |











Insulation tube packed in export standard carton. OEM can be supplied.


It improves building energy efficiency, reduces exterior noise, absorbs reverberating sounds inside the building, and offers high thermal efficiency to keep buildings warmer in winter and cooler in summer.
It is widely used in large-scale central and domestic air conditioning systems, building construction, chemical processing, textile manufacturing, and various electrical industries.
The material features low thermal conductivity: ≤0.030 W/(m.k) at -20°C, ≤0.032 W/(m.k) at 0°C, and ≤0.036 W/(m.k) at 40°C, as tested by ASTM C 518 standards.
It achieves Class 0 & Class 1 fire ratings according to BS 476 Part 6 and Part 7 tests, and features an Oxygen Index of ≥36.
Yes, it demonstrates good resistance against fungi, ozone, U.V. radiation, and general weathering, complying with ASTM and GB test methods.
The insulation tubes are packed in standard export cartons, and OEM customization services can be provided upon request.