Wholesale NBR PVC NITRILE RUBBER FOAM INSULATION SHEET ROLL Factories, Pricelist

Kingflex NBR PVC NITRILE RUBBER FOAM INSULATION SHEET ROLL is with excellent performance of nitrile rubber and polyvinyl chloride as the main material, through the special process of burying, curing, foaming and other processes produced.

Product Description

NBR PVC NITRILE RUBBER FOAM INSULATION SHEET ROLL is soft heat-insulating, heat-preservation and energy conservation materials using butyronitrile rubber with best performance and polyvinyl Chloride (NBR & PVC) as main raw materials and other high quality auxiliary materials through foaming and so on special procedure.
Dimension Sheet
Thickness Width 1m Width 1.2m Width 1.5m
Inches mm Size(L*W) ㎡/Roll Size(L*W) ㎡/Roll Size(L*W) ㎡/Roll
1/4" 6 30 × 1 30 30 × 1.2 36 30 × 1.5 45
3/8" 10 20 × 1 20 20 × 1.2 24 20 × 1.5 30
1/2" 13 15 × 1 15 15 × 1.2 18 15 × 1.5 22.5
3/4" 19 10 × 1 10 10 × 1.2 12 10 × 1.5 15
1" 25 8 × 1 8 8 × 1.2 9.6 8 × 1.5 12
1 1/4" 32 6 × 1 6 6 × 1.2 7.2 6 × 1.5 9
1 1/2" 40 5 × 1 5 5 × 1.2 6 5 × 1.5 7.5
2" 50 4 × 1 4 4 × 1.2 4.8 4 × 1.5 6
Technical Data
Property Unit Value Test Method
Temperature range °C (-50 - 110) GB/T 17794-1999
Density range Kg/m3 45-65Kg/m3 ASTM D1667
Water vapor permeability Kg/(m.s.pa) ≤0.91×10 ﹣¹³ DIN 52 615 / BS 4370 Part 2 1973
μ - ≥10000 -
Thermal Conductivity W/(m.k) ≤0.030 (-20°C) ASTM C 518
≤0.032 (0°C)
≤0.036 (40°C)
Fire Rating - Class 0 & Class 1 BS 476 Part 6 part 7
Flame Spread and Smoke Developed Index 25/50 ASTM E 84
Oxygen Index ≥36 GB/T 2406, ISO4589
Water Absorption,% by Volume % 20% ASTM C 209
Dimension Stability ≤5 ASTM C534
Fungi resistance - Good ASTM 21
Ozone resistance Good GB/T 7762-1987
Resistance to U.V. and weather Good ASTM G23
Key Benefits & Features
Improve the energy efficiency of the building.
Reduce transmission of exterior sound to the interior of the building.
Absorb reverberating sounds within the building.
Provide thermal efficiency and great thermal insulation with low thermal conductivity.
Low moisture & water absorption, resistant to water vapour.
Ideal for Building & construction industry with durable & good strength to deformation.
Deliver an excellent cushioning & shock absorption. Non-toxic material & safe for children.
Strong against abrasions and offer excellent adhesion to adhesives and coatings.
Condensation Control: The elastomeric, nitrile rubber foam pipe insulation prevents condensation on refrigeration copper piping, heating and ventilation pipework, and air-conditioning pipework.
Versatile Applications: There isn’t much nitrile rubber foam pipe lagging cannot do for you. When insulated properly and when working within its claimed temperature range, the rubber foam lagging saves energy loss in both hot and cold plumbing lines, as well as a ducting insulation blanket.
The insulation is easy to cut, carry and install. Installing nitrile rubber lagging on pipes is an easy DIY task that significantly reduces energy costs. It operates efficiently in a wide temperature range of -50 °C to +110 °C. The nitrile rubber pipe insulation increases the life of your plumbing in industrial, commercial and residential applications. They are cost-effective, easy to install and highly flexible.
NBR/PVC vs EPDM Insulation: Closed cell elastomeric insulation, also known as rubber, has been commercially available for almost 70 years. It’s commonly specified to insulate below-ambient (cold) mechanical systems such as HVAC, VRF/VRV, refrigeration, chilled water, medical gas, and cold water plumbing piping.
For the choice in building materials, analysis and comparisons are vital to make a correct product selection. Whether you are choosing cladding material for a skyscraper, or an insulation product for an HVAC or plumbing system, ensuring application and building codes requirements are met is crucial to an effective and compliant install. Variables like temperature, density, water permeability, or UV resistance can all impact a successful project selection.
There are options for almost every application and need. Two of the most common elastomeric insulation materials for HVAC, chilled water, and refrigeration systems are based on nitrile butadiene rubber (NBR) and ethylene propylene diene monomer rubber (EPDM) technology. Both of these elastomeric foams are flexible, closed cell, and have a high resistance to moisture and water ingress. In fact, their water permeability is so low that they do not generally require additional water-vapor retarders. Also, with such high vapor resistance and surface emissivity, these elastomeric foams do an excellent job at preventing surface condensation formation.
Different Strengths and different Applications: Even though NBR and EPDM seem to be similar, there are some key differences. NBR is a non-aromatic polymer compound, whereas EPDM is an aromatic polymer. Moreover, NBR is made using acrylonitrile and butadiene monomers, while EPDM is made using ethylene, propylene and a diene comonomer. Another significant difference in terms of application, is that NBR has a temperature range of -40F to 180F, while EPDM has a wider operating temperature range of -65°F to 250°F.
NBR stands alone as the most oil- and fuel-resistant elastomer. It is also known for maintaining its stability in low temperatures. On the other hand, EPDM is a heat, ozone, and UV-resistant rubber that has a great tensile strength, aging resistance, and abrasion resistance, as well as having a lower smoke density with average flame development especially at 1-1/2 and 2” thicknesses.
Both rubber cellular foam insulation products are proven alternatives to fiberglass on HVAC, chilled water, and refrigerant systems (piping, pumps, tanks, vessels, and spheres) due to its hydrophobic chemical composition, closed-cell structure, and built-in vapor retarders.
Frequently Asked Questions
What is nitrile rubber pipe insulation made of?
The nitrile rubber pipe insulation is made of nitrile rubber or Buna R, a most commonly used elastomer. Nitrile rubber consists of unsaturated copolymers of acrylonitrile and butadiene monomers. The chemical and physical properties of nitrile rubber vary based on the polymer makeup.
What is the difference between NBR/PVC and EPDM Insulation?
NBR is a non-aromatic polymer made using acrylonitrile and butadiene monomers, with a temperature range of -40°F to 180°F, and is highly oil- and fuel-resistant. EPDM is an aromatic polymer made using ethylene, propylene and a diene comonomer, with a wider operating temperature range of -65°F to 250°F, and offers higher heat, ozone, and UV resistance.
Do these elastomeric foam insulations require additional water-vapor retarders?
Generally, no. Both NBR and EPDM elastomeric foams are flexible, closed cell, and have an exceptionally high resistance to moisture and water ingress. Their water permeability is so low that additional water-vapor retarders are usually not required.
What is the operating temperature range for nitrile rubber insulation?
Nitrile rubber insulation operates efficiently in a wide temperature range from -50 °C to +110 °C (and specifically -40°F to 180°F for NBR compounds).
How does nitrile rubber insulation prevent condensation?
Due to its closed-cell structure, low water-vapor permeability, and high surface emissivity, the elastomeric insulation prevents moisture build-up and surface condensation formation on refrigeration, heating, ventilation, and air-conditioning pipework.
Why is rubber cellular foam insulation preferred over fiberglass?
Rubber cellular foam insulation is preferred for HVAC, chilled water, and refrigerant systems because of its hydrophobic chemical composition, closed-cell structure, and built-in vapor retarders, which ensure long-term thermal efficiency and moisture resistance.